The X2 series balances feature the latest generation capacitive display providing the maximum comfort of use, available right at your fingertips. Ease of operation, clear menu and practical arrangement of the display guarantee the best ergonomics for your everyday tasks. A wide array of available interfaces facilitate selection of the most optimal means for communication.
WTC 200
WLC 0.2.X2
WTC 600,  WTC 2000
WLC 2.X2, WLC 6.X2, WLC 1/10.X2, WLC 10.X2, WLC 20.X2
call us

Specifications Chart

RADWAG WLC-X2 Series Precision Balances

For a limited time only
Add to Cart to see Lower Price

The WLC.X2 series represents a new advanced level for precision balances. The X2 series balances feature the latest generation capacitive display providing the maximum comfort of use, available right at your fingertips. Ease of operation, clear menu and practical arrangement of the display guarantee the best ergonomics for your everyday tasks. A wide array of available interfaces facilitate selection of the most optimal means for communication. The X2 series balances offer unlimited possibilities for cooperation with external devices, providing printing, copying, archiving and data transfer.

Built-in IR sensors allow numerous operations (e.g. tarring, transmitting the result to a printer or selecting successive steps of a particular process, etc.) to be performed handsfree, by simply moving a hand across the sensor. The housing is made of plastic, and the pan is made of stainless steel.

Databases in X2 series balances
In new WLC.X2 series balances the information system is based on 7 databases which allow several users to work with database storing several products. The registered weighing results can be subject to further analysis.
  • The data is registered in 7 databases:
  • Users (up to 100 users),
  • Products (up to 5 000 products),
  • Weighments (up to 50 000 weighments),
  • Packaging (up to 100 packaging types),
  • Formulas (up to 100 formulas),
  • Clients (up to 100 clients),
  • ALIBI memory (up to 500 000 weighments).
    The X2 series features option of making reports of 2 different categories:
  • Reports on formulas (up to 200 reports),
  • Reports on density determination (up to 500 reports),

ALIBI Memory
The X2 series balances feature ALIBI memory that is a warranty for safety and automatic recording of your measurements. Options such as data preview, copying and archiving are available to users as well. The ALIBI memory allows to record up to 500 000 weighment records.

Personalization taken to the next level The X2 is the only balance available on the market that provides a user with the option to design display using wide selection of widgets. Customised display of X2 series offers direct access to the results of your work and other important information directly from the home screen.

Weighing Data Management USB interface facilitates quick transfer and copying of any results of your work (measurements, reports, databases) to other balances. Network management of the weighing data increases effectivity, productivity and safety of the important data to the maximum.

  • AUTOTEST - Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
  • CHECKWEIGHING - Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual /- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
  • DOSING - Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
  • PARTS COUNTING - Function using mass measurement for determination of measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
  • PERCENT SETUP - Percent setup function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly excessed.
  • GLP PROCEDURES - Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
  • STATISTICS - Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
  • TOTALIZING - Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
  • >UNDER HOOK WEIGHING - UNDER HOOK WEIGHING
  • ANIMAL WEIGHING - Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimaze the function depending on the measured product characteristics.
  • DENSITY DETERMINATION - Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of under-pan weighing. Tested load of significant size may be measured this way.
  • PEAK HOLD - Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
  • Ambient conditions monitoring
  • Newton unit measurement
  • Replaceable units
  • ALIBI Memory
Model WLC 0.2.X2 WLC 0.6.X2 WLC 2.X2 WLC 6.X2 WLC 1/10.X2 WLC 10.X2 WLC 20.X2 WLC 21.X2
Price RADWAG WLC 0.2.X2  Precis
$858.50
buy now
RADWAG WLC 0.6.X2  Precis
$742.90
buy now
RADWAG WLC 2.X2  Precisio
$801.55
buy now
RADWAG WLC 6.X2 Precision
$742.90
buy now
RADWAG WLC 1/10.X2 Precis
$858.50
buy now
RADWAG WLC 10.X2 Precisio
$774.00
buy now
RADWAG WLC 20.X2  Precisi
$801.55
buy now
RADWAG WLC 21.X2  Precisi
$743.00
buy now
Capacity x Readability 200 g x 0.001 g 600 g x 0.01 g 2000 g x 0.01 g 6000 g x 0.1 g 1000 g x 0.01 g
10 kg x 0.1 g
10 kg x 0.1 g 20 kg x 0.1 g 21 kg x 1 g
Tare range -200 g -600 g -2000 g -6000 g -10000 g -10000 g -20000 g -21000 g
Linearity ±0.003 g ±0.03 g ±0.03 g ±0.3 g ±0.03 g / ±0.3 g ±0.3 g ±0.3 g ±3 g
Repeatability 0.0014 g 0.008 g 0.015 g 0.1 g 0.015 g / 0.08 g 0.08 g 0.1 g 0.8 g
Working temperature +10 - +40 °C
Pan size Ø 100 mm 128×128 mm 195×195 mm
Stabilization time 2 s 4 s / 2 s 2 s 3 s
Display 5" color capacitive touchscreen
Power supply 12 ÷ 16 V DC / 250 mA (350 mA for scales with Wireless Connection)
Interface 2×RS232, USB-A, USB-B, Wireless Module, Ethernet
Adjustment / Calibration internal external
IP rating IP 43
Database 7 databases
Net weight/Gross weight 1.8 kg / 3.4 kg 2.2 kg / 3.8 kg
    Accessoriies::
  • Antivibration table for laboratory balances
  • Antivibration table SAL/STONE
  • Impact printer Epson, Printer USB PCL
  • Density determination kit
  • Rack for under hook weighing
  • "Tare" or "Print" foot button
  • PC keyboard USB
  • External USB memory (FAT files format)
  • Bar code scanner
  • Bar code scanner USB HID
  • Power loop output AP2-1 (plastic housing)
  • Additional LCD display "WD-6"
  • Power adapter with battery and charger ZR-02
  • Mass standard
  • USB A- USB B cable (balance - computer, balance - PLC printer)
  • Cable RS 232 (scale - computer) "P0108"
  • Cable RS 232 (scale, Epson printer) "P0151"
  • "PW-WIN", "RAD-KEY" computer software


 

 

 

 

 

Your account Search Contact Us Store Directory Home page Your account Contact Us Search our site Site map and product categories